WARNING Ground L1 L2 Fig. 5 Power requirements 240 V, 1 PH, 60 Hz Look at the name plate loca-ted on the heat pump to know the required amperage. Please refer to your local electrical code for additional wiring requirements. OWNER'S MANUAL 11. R-410A, also known as Puron, is arguably becoming one of the most popular refrigerants in the world. It rose to prominence here in the United States in the year 2010 when it's predecessor, the HCFC R-22, was banned due to the Chlorine that it contained.
*SX14 R-410A Remote
Condensing Unit
ASX140181BA
ASX140181CA
ASX140241BA
ASX140241CA
ASX140301BA
ASX140301CA
ASX140361BA
ASX140361CA
ASX140421CA
ASX140421DA
ASX140481BA
ASX140481CA
ASX140601BA
SSX140181BA
SSX140241BA
SSX140301BA
SSX140361BA
SSX140421CA
SSX140481BA
This manual is to be used by qualified technicians only. | This manual replaces RP-536D | |
© 2009-2010 Goodman Manufacturing Company, L.P. ◊ 5151 San Felipe, Suite 500 ◊ Houston, TX 77056 | ||
Black sims 4 cc hair. RP-536E | www.goodmanmfg.com www.amana-hac.com | November 2010 |
Important Information | |
Index | |
Functional Parts List .................................................. | 3 |
Illustration and Parts .................................................. Fallout weapon retexture project. | 4 - 11 |
Views shown are for parts illustrations only, not servicing procedures.
Revision E: Added model SSX140481BA.
Text Codes:
AR - As Required
NA - Not Available
NS - Not Shown
00000000 - See Note
QTY - Quantity | Example (QTY 3) (If Quantity not shown, Quantity = 1) |
M - Model | Example (M1) (If M Code not shown, then part is used on all Models) |
Expanded Model Nomenclature: | |
Example | |
M1 - Model#1 | |
M2 - Model#2 | |
M3 - Model#3 |
Goodman Manufacturing Company, L.P. is not responsible for personal injury or property damage resulting from improper service. Review all service information before beginning repairs.
Warranty service must be performed by an authorized technician, using authorized factory parts. If service is required after the warranty expires, Goodman Manufacturing Company, L.P. also recommends contacting an authorized technician and using authorized factory parts.
Goodman Manufacturing Company, L.P. reserves the right to discontinue, or change at any time, specifications or designs without notice or without incurring obligations.
For assistance within the U.S.A. contact:
Consumer Affairs Department Goodman Manufacturing Company, L.P. 7401 Security Way
Houston, Texas 77040 877-254-4729-Telephone 713-863-2382-Facsimile
For assistance outside the U.S.A. contact:
International Division
Goodman ManufCompany,cturingL.P.Company, L.P.
7401 Security Way Houston, Texas 77040 713-861-2500-Telephone 713-863-2382-Facsimile
Functional Parts
Part
No: Description:
0151R00002P 3/4' SERVICE VALVE OPEN LEFT (M1, M2, M3, M4, M5, M6, M7, M8, M14, M15, M16, M17)
0130M00011P LOW AMBIENT THERMOSTAT, SPDT (M1, M2, M3, M4, M5, M6, M7, M8, M9, M10, M11, M12, M13)
B12825171 | 3/8' SERVICE VALVE |
0151R00003P | 7/8' SERVICE VALVE OPEN LEFT (M9, M10, |
M11, M12, M13, M18, M19) | |
CAP050300440RSS | CAPACITOR 5/30/370V (M1, M2, M14) |
CAP050350440RSS | CAPACITOR 5/35/440V (M3, M4, M15) |
CAP050400440RT | CAPACITOR 5/40/440V (M5, M6, M16) |
CAP050450440RT | CAPACITOR 5/45/440V (M7, M8, M9, M10, |
M11, M12, M17, M18, M19) | |
CAP050700440RTS | CAPACITOR 5/70/440V (M13) |
543001001 | COMFORT ALERT MODULE (M2, M4, M6, M8, |
M10, M11, M12, M13) | |
543001000S | COMFORT ALERT MODULE (M1, M3, M5, M7, |
M9) | |
ZP20K5EPFV130 | COMPRESSOR 20000, 208/230/60/1 (M3, M4, |
M15) | |
ZP24K5EPFV130 | COMPRESSOR 24000, 208/230/60/1 (M5, M6, |
M16) | |
ZP29K5EPFV130 | COMPRESSOR 29000, 208/230/60/1 (M7, M8, |
M17) | |
ZP31K5EPFV830 | COMPRESSOR 31100, 208/230/60/1 (M9, |
M10, M18) | |
ZP38K5EPFV130 | COMPRESSOR 37500, 208/230/60/1 (M11, |
M12, M19) | |
ZP51K5EPFV830 | COMPRESSOR 51000, 208/230/60/1 (M13) |
ZP16K5EPFV130 | COMPRESSOR15500, 208/230/60/1 (M1, M2, |
M14) | |
0131M00019P | COND MOTOR 1/12 HP, 1 SP, 8 PL (M15) |
0131M00027 | COND MOTOR 1/12 HP, 2 SP, 8 PL (M3, M4) |
0131M00061S | COND MOTOR 1/4 HP, 1 SP, 8 PL (M19) |
0131M00015PS | COND MOTOR 1/4 HP, 2 SP, 8 PL (M11, M12, |
M13) | |
0131M00060S | COND MOTOR 1/6 HP, 1 SP, 8 PL (M14, M16, |
M17, M18) | |
0131M00017PS | COND MOTOR 1/6 HP, 2 SP, 8 PL (M1, M2, |
M5, M6, M7, M8, M9, M10) | |
CONT1P025024VS | CONTACTOR 25 AMP, 1P, 24V (M1, M2, M3, |
M4, M5, M6, M7, M8, M9, M10, M14, M15, M16, | |
M17, M18) |
0130M00082 | LOW PRESSURE SWITCH (M12, M19) |
0130R00001 | LOW PRESSURE SWITCH (M1, M2, M3, M4, |
M5, M6, M7, M8, M9, M10, M11, M13, M14, | |
M15, M16, M17, M18) |
SPECIAL PARTS
0161R00008P AMANA LOGO CAP (M1, M2, M3, M4, M5, M6, M7, M8, M9, M10, M11, M12, M13)
0161R00010P | AMANA NAMEPLATE (M1, M2, M3, M4, M5, |
M6, M7, M8, M9, M10, M11, M12, M13) | |
IO-258J | INSTRUCTION, INST |
0161R00009P | NAMEPLATE (M14, M15, M16, M17, M18, M19) |
Expanded Model Nomenclature
M1 - ASX140181BA
M2 - ASX140181CA
M3 - ASX140241BA
M4 - ASX140241CA
M5 - ASX140301BA
M6 - ASX140301CA
M7 - ASX140361BA
Tenma 72-410a Manual
M8 - ASX140361CA
M9 - ASX140421CA
M10 - ASX140421DA
M11 - ASX140481BA
M12 - ASX140481CA
M13 - ASX140601BA
Tenma 72 410a Manual
WARNING Ground L1 L2 Fig. 5 Power requirements 240 V, 1 PH, 60 Hz Look at the name plate loca-ted on the heat pump to know the required amperage. Please refer to your local electrical code for additional wiring requirements. OWNER'S MANUAL 11. R-410A, also known as Puron, is arguably becoming one of the most popular refrigerants in the world. It rose to prominence here in the United States in the year 2010 when it's predecessor, the HCFC R-22, was banned due to the Chlorine that it contained.
*SX14 R-410A Remote
Condensing Unit
ASX140181BA
ASX140181CA
ASX140241BA
ASX140241CA
ASX140301BA
ASX140301CA
ASX140361BA
ASX140361CA
ASX140421CA
ASX140421DA
ASX140481BA
ASX140481CA
ASX140601BA
SSX140181BA
SSX140241BA
SSX140301BA
SSX140361BA
SSX140421CA
SSX140481BA
This manual is to be used by qualified technicians only. | This manual replaces RP-536D | |
© 2009-2010 Goodman Manufacturing Company, L.P. ◊ 5151 San Felipe, Suite 500 ◊ Houston, TX 77056 | ||
Black sims 4 cc hair. RP-536E | www.goodmanmfg.com www.amana-hac.com | November 2010 |
Important Information | |
Index | |
Functional Parts List .................................................. | 3 |
Illustration and Parts .................................................. Fallout weapon retexture project. | 4 - 11 |
Views shown are for parts illustrations only, not servicing procedures.
Revision E: Added model SSX140481BA.
Text Codes:
AR - As Required
NA - Not Available
NS - Not Shown
00000000 - See Note
QTY - Quantity | Example (QTY 3) (If Quantity not shown, Quantity = 1) |
M - Model | Example (M1) (If M Code not shown, then part is used on all Models) |
Expanded Model Nomenclature: | |
Example | |
M1 - Model#1 | |
M2 - Model#2 | |
M3 - Model#3 |
Goodman Manufacturing Company, L.P. is not responsible for personal injury or property damage resulting from improper service. Review all service information before beginning repairs.
Warranty service must be performed by an authorized technician, using authorized factory parts. If service is required after the warranty expires, Goodman Manufacturing Company, L.P. also recommends contacting an authorized technician and using authorized factory parts.
Goodman Manufacturing Company, L.P. reserves the right to discontinue, or change at any time, specifications or designs without notice or without incurring obligations.
For assistance within the U.S.A. contact:
Consumer Affairs Department Goodman Manufacturing Company, L.P. 7401 Security Way
Houston, Texas 77040 877-254-4729-Telephone 713-863-2382-Facsimile
For assistance outside the U.S.A. contact:
International Division
Goodman ManufCompany,cturingL.P.Company, L.P.
7401 Security Way Houston, Texas 77040 713-861-2500-Telephone 713-863-2382-Facsimile
Functional Parts
Part
No: Description:
0151R00002P 3/4' SERVICE VALVE OPEN LEFT (M1, M2, M3, M4, M5, M6, M7, M8, M14, M15, M16, M17)
0130M00011P LOW AMBIENT THERMOSTAT, SPDT (M1, M2, M3, M4, M5, M6, M7, M8, M9, M10, M11, M12, M13)
B12825171 | 3/8' SERVICE VALVE |
0151R00003P | 7/8' SERVICE VALVE OPEN LEFT (M9, M10, |
M11, M12, M13, M18, M19) | |
CAP050300440RSS | CAPACITOR 5/30/370V (M1, M2, M14) |
CAP050350440RSS | CAPACITOR 5/35/440V (M3, M4, M15) |
CAP050400440RT | CAPACITOR 5/40/440V (M5, M6, M16) |
CAP050450440RT | CAPACITOR 5/45/440V (M7, M8, M9, M10, |
M11, M12, M17, M18, M19) | |
CAP050700440RTS | CAPACITOR 5/70/440V (M13) |
543001001 | COMFORT ALERT MODULE (M2, M4, M6, M8, |
M10, M11, M12, M13) | |
543001000S | COMFORT ALERT MODULE (M1, M3, M5, M7, |
M9) | |
ZP20K5EPFV130 | COMPRESSOR 20000, 208/230/60/1 (M3, M4, |
M15) | |
ZP24K5EPFV130 | COMPRESSOR 24000, 208/230/60/1 (M5, M6, |
M16) | |
ZP29K5EPFV130 | COMPRESSOR 29000, 208/230/60/1 (M7, M8, |
M17) | |
ZP31K5EPFV830 | COMPRESSOR 31100, 208/230/60/1 (M9, |
M10, M18) | |
ZP38K5EPFV130 | COMPRESSOR 37500, 208/230/60/1 (M11, |
M12, M19) | |
ZP51K5EPFV830 | COMPRESSOR 51000, 208/230/60/1 (M13) |
ZP16K5EPFV130 | COMPRESSOR15500, 208/230/60/1 (M1, M2, |
M14) | |
0131M00019P | COND MOTOR 1/12 HP, 1 SP, 8 PL (M15) |
0131M00027 | COND MOTOR 1/12 HP, 2 SP, 8 PL (M3, M4) |
0131M00061S | COND MOTOR 1/4 HP, 1 SP, 8 PL (M19) |
0131M00015PS | COND MOTOR 1/4 HP, 2 SP, 8 PL (M11, M12, |
M13) | |
0131M00060S | COND MOTOR 1/6 HP, 1 SP, 8 PL (M14, M16, |
M17, M18) | |
0131M00017PS | COND MOTOR 1/6 HP, 2 SP, 8 PL (M1, M2, |
M5, M6, M7, M8, M9, M10) | |
CONT1P025024VS | CONTACTOR 25 AMP, 1P, 24V (M1, M2, M3, |
M4, M5, M6, M7, M8, M9, M10, M14, M15, M16, | |
M17, M18) |
0130M00082 | LOW PRESSURE SWITCH (M12, M19) |
0130R00001 | LOW PRESSURE SWITCH (M1, M2, M3, M4, |
M5, M6, M7, M8, M9, M10, M11, M13, M14, | |
M15, M16, M17, M18) |
SPECIAL PARTS
0161R00008P AMANA LOGO CAP (M1, M2, M3, M4, M5, M6, M7, M8, M9, M10, M11, M12, M13)
0161R00010P | AMANA NAMEPLATE (M1, M2, M3, M4, M5, |
M6, M7, M8, M9, M10, M11, M12, M13) | |
IO-258J | INSTRUCTION, INST |
0161R00009P | NAMEPLATE (M14, M15, M16, M17, M18, M19) |
Expanded Model Nomenclature
M1 - ASX140181BA
M2 - ASX140181CA
M3 - ASX140241BA
M4 - ASX140241CA
M5 - ASX140301BA
M6 - ASX140301CA
M7 - ASX140361BA
Tenma 72-410a Manual
M8 - ASX140361CA
M9 - ASX140421CA
M10 - ASX140421DA
M11 - ASX140481BA
M12 - ASX140481CA
M13 - ASX140601BA
Tenma 72 410a Manual
M14 - SSX140181BA
M15 - SSX140241BA
M16 - SSX140301BA
Tenma 72 410a Manual
M17 - SSX140361BA
M18 - SSX140421CA
M19 - SSX140481BA
CONT1P030024VS | CONTACTOR 30 AMP, 1P, 24V (M11, M12, |
M13, M19) | |
0150M00001P | FAN BLADE 20 INCH (M3, M4, M15) |
0150M00012S | FAN BLADE 20' CCW (M1, M2, M14) |
0150M00008S | FAN BLADE 22' TNT2203-25 (M7, M8, M9, |
M10, M17) | |
10625738S | FAN BLADE 26' ALUM CCW (M11, M12, M13, |
M19) | |
B1086764S | FAN BLADE TYPE 2 (M5, M6, M16, M18) |
20322603 | HIGH PRESSURE SWITCH |
Top Panel Assembly
Why Do I need R-410a Certification?
Although R-410A certification is not yet mandatory, it is becoming a common requirement for many companies' employees. It is important to note that there are significant liabilities associated with not having this certification, as R410-A operates at much higher pressures than R-22 and is not safe to use in the same operating systems. The use of R410-A will always require some change in the system design. Additionally, failure to obtain R410-A certification represents a potential loss of business to technicians, as the use of R-410A is on the rise.
What is the exam like?
The R-410a Certification Examination is an open book exam that consists of 25 multiple choice questions. You must receive a score of 18 or 72% or more to pass. The exam is FREE. If you wish to receive a R-410a Certification Card, Wall Certificate and letter of accomplishment you may purchase one at the end of completing the exam with proof TypeII or Universal Section 608 Certification . You can download REPA's R-410a manual for free on the link below.